13:11. System of heating

Control panel of a heater
Disconnect a wire from the negative plug of the rechargeable battery.
The screw-driver wring out the conditioner switch from the block of rotary ventilating grates and disconnect the socket for access to screws of fastening of the control panel of a heater.

Fig. 13.49. Heater: 1 – air duct No. 5; 2 – right rotary ventilating grate; 3 – air duct No. 4; 4 – fan air duct; 5 – block of rotary lattices; 6 – central air duct; 7 – central rotary ventilating grates; 8 – forward air duct of a heater; 9 – control panel; 10 – right back air duct of a heater; 11 – left back air duct of a heater; 12 – air duct No. 1; 13 – air duct No. 2; 14 – left rotary ventilating grate; 15 – air duct No. 3; 16 – additional side air duct; 17 – heater fan; 18 – air duct; 19 – heater; 20, 22 – a glass heater air duct; 21 – glass heater lattice; 23 – panel of rotary ventilating grates


Turn out screws and remove the control panel of a heater from the dashboard (fig. 13.49).
Disconnect the socket from the control panel of a heater.
Disconnect cables from the control panel of a heater.
Installation is carried out to the sequences, the return to removal. Connect and adjust cables.

Cables of management of a heater
Cable of management of distribution of streams of air

Fig. 13.50. Adjustment of a cable of distribution of streams of air: 1 – glass heating; 2 – ventilation of salon; 3 – course size


Install the handle of management in the provision of heating, and translate the handle of distribution of streams of air against the stop forward. After that connect a cable and establish a clip (fig. 13.50).
Connect a wire to the negative plug of the rechargeable battery, turn the fan switch in situation "4" and check that there was no leak of air through the central and lower air ducts.
Cable of management of temperature

Fig. 13.51. Adjustment of a cable of management of temperature: 1 – cold air; 2 – warm air


Turn the handle of management of temperature in situation "cold" and move the lever of switching of cold/warm air to the extreme provision of supply of cold air then connect a cable and a clip (fig. 13.51).
The lever of switching has to move from extreme left to extreme right situation.
Cable of switching of the recirculated / fresh air
Extend against the stop the handle of distribution of streams of air.

Fig. 13.52. Fastening of a cable of switching of the recirculated / fresh air: And – course size


After the cable of switching of the recirculated / fresh air is extended against the stop in a provision of recirculation, connect a cable and establish a clip (fig. 13.52).
Check work of a cable, having several times moved the handle of management from one extreme situation to another.