2.22. Adjustment of the course of a pedal of coupling

Press a coupling pedal before emergence of considerable resistance at which coupling switching off process begins, and measure by a ruler a free wheeling of a pedal. It has to correspond precisely to a certain value, otherwise it is necessary to execute adjustment.
After adjustment of a free wheeling check height of installation of a pedal of coupling for what measure distance from the platform of a pedal to a partition of a motor compartment and compare the received value to specifications.

Fig. 2.16. Adjustment of a pedal of coupling: 1 – free wheeling of a pedal; 2 – pedal height at the switched-off coupling; 3 – pedal height at the included coupling; 4 – lock-nut; 5 – lock adjusting bolt


For adjustment of height of a pedal of coupling remove the heater air duct located under the dashboard. Weaken a lock-nut of 4 (fig. 2.16) and adjust pedal height, turning a lock adjusting bolt 5. After the end of adjustment reliably tighten a lock-nut.

Fig. 2.17. Adjustment of the course of a pedal of coupling on the coupling switching off lever: 1 – adjusting nut; 2 – lock bolt; 3 – free wheeling of the lever of switching off of coupling


For adjustment of the course of a pedal press the lever of switching off of coupling in a motor compartment, at the same time pulling a cable, and check the course of a pedal (fig. 2.17). Weaken a lock-nut and adjust the pedal course, turning an adjusting nut 1. Before an inhaling of a lock-nut check the course of a pedal and the course of a control lever coupling.